X106
2Hours |
X104
3Hours |
X101
4Hours |
| OD of Pipe |
Shell Size |
Wt. |
Shell Size |
Wt. |
Shell Size |
Wt. |
| 3 1/2" |
6x6 |
23 |
7x7 |
31 |
8x8 |
39 |
| 4" |
6x6 |
22 |
7x7 |
30 |
9x9 |
53 |
| 4 1/2" |
7x7 |
28 |
8x8 |
37 |
9x9 |
52 |
| 5 1/2" |
8x8 |
33 |
9x9 |
49 |
10x10 |
59 |
| 6 5/8" |
9x9 |
44 |
10x10 |
55 |
11x11 |
51 |
| 8 5/8" |
11x11 |
41 |
12x12 |
69 |
13x13 |
63 |
| 10 3/4" |
13x13 |
50 |
14x14 |
63 |
15x15 |
76 |
| 12 3/4" |
15x15 |
61 |
16x16 |
75 |
17x17 |
89 |
Weight shown in pounds per
foot for shell and fireproofing only.
All shell sizes are shown in inches.
Information available upon request for sizes other than shown.
Refer to latest edition of A.I.S.C. steel construction manual for allowable safe loads. |
|
Concrete Filled Steel Pipe
ALLOWABLE SAFE LOAD IN KIPS* |
|
|
Effective Length in Feet - KL
with Respect to Radius of Gyration |
OD of
Pipe |
|
Wall
Thickness |
Weight
per Ft. |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
26 |
| 3 1/2" |
HW |
0.216 |
15 |
45 |
40 |
32 |
|
|
|
|
|
|
|
|
| XHW |
0.300 |
17 |
58 |
49 |
39 |
|
|
|
|
|
|
|
|
| XXHW |
0.600 |
23 |
94 |
79 |
60 |
|
|
|
|
|
|
|
|
| 4" |
HW |
0.226 |
20 |
58 |
53 |
45 |
36 |
|
|
|
|
|
|
|
| XHW |
0.318 |
22 |
75 |
66 |
56 |
46 |
|
|
|
|
|
|
|
| 4 1/2" |
HW |
0.237 |
24 |
73 |
66 |
59 |
51 |
41 |
|
|
|
|
|
|
| XHW |
0.337 |
27 |
93 |
86 |
76 |
65 |
52 |
|
|
|
|
|
|
| XXHW |
0.674 |
36 |
155 |
139 |
122 |
102 |
|
|
|
|
|
|
|
| 5 1/2" |
HW |
0.258 |
36 |
106 |
99 |
92 |
85 |
75 |
66 |
54 |
|
|
|
|
| XHW |
0.375 |
39 |
139 |
130 |
120 |
110 |
98 |
84 |
69 |
|
|
|
|
| XXHW |
0.750 |
52 |
230 |
215 |
198 |
178 |
156 |
132 |
|
|
|
|
|
| 6 5/8" |
HW |
0.280 |
49 |
144 |
139 |
132 |
123 |
114 |
104 |
93 |
81 |
68 |
|
|
| XHW |
0.432 |
56 |
197 |
188 |
178 |
166 |
153 |
140 |
125 |
109 |
|
|
|
| XXHW |
0.864 |
73 |
327 |
312 |
293 |
272 |
249 |
225 |
198 |
169 |
|
|
|
| 8 5/8" |
HW |
0.322 |
81 |
232 |
225 |
218 |
210 |
201 |
190 |
179 |
167 |
154 |
141 |
127 |
| XHW |
0.500 |
91 |
314 |
305 |
295 |
283 |
270 |
257 |
242 |
226 |
209 |
191 |
171 |
| XXHW |
0.875 |
111 |
475 |
460 |
444 |
425 |
404 |
383 |
359 |
334 |
307 |
278 |
248 |
| 10 3/4" |
HW |
0.365 |
123 |
342 |
336 |
328 |
320 |
311 |
300 |
289 |
277 |
264 |
251 |
237 |
| XHW |
0.500 |
133 |
423 |
415 |
406 |
394 |
383 |
370 |
356 |
342 |
326 |
309 |
291 |
| 12 3/4" |
HW |
0.375 |
169 |
442 |
437 |
429 |
421 |
412 |
402 |
391 |
380 |
368 |
355 |
341 |
| XHW |
0.500 |
178 |
534 |
526 |
517 |
507 |
496 |
484 |
470 |
457 |
442 |
426 |
409 |