Fire-Trol Columns (Square Type SS) |
| UL RATED FIREPROOFED COLUMNS |
OD of
Tubing |
X106 - 2 Hour |
X104 - 3 Hour |
X101 - 4 Hour |
| Shell Size |
Wt. |
Shell Size |
Wt. |
Shell Size |
Wt. |
| 3x3 |
6x6 |
24 |
7x7 |
31 |
8x8 |
39 |
| 3½ x 3½ |
6x6 |
22 |
7x7 |
30 |
8x8 |
38 |
| 4x4 |
6x6 |
21 |
7x7 |
28 |
8x8 |
36 |
| 5x5 |
7x7 |
25 |
8x8 |
33 |
9x9 |
48 |
| 6x6 |
8x8 |
29 |
9x9 |
44 |
10x10 |
54 |
| 7x7 |
9x9 |
39 |
10x10 |
49 |
11x11 |
45 |
| 8x8 |
10x10 |
43 |
11x11 |
39 |
12x12 |
67 |
| 10x10 |
12x12 |
52 |
13x13 |
47 |
14x14 |
59 |
Weight shown in pounds per foot
for shell and fireproofing
only.
All shell sizes are shown in inches.
Information available upon request for sizes other than shown.
Refer to latest edition of A.I.S.C. steel construction manual for allowable safe loads. |
|
| |
Concrete Filled Steel Tubing
ALLOWABLE SAFE LOAD IN KIPS** |
| |
|
Effective Length in Feet - KL with Respect to Radius of Gyration |
| OD of Pipe Tubing |
Wall
Thickness |
Weight
per Ft. |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
26 |
28 |
| 3x3 |
1/4 |
15 |
62 |
53 |
40 |
|
|
|
|
|
|
|
|
|
| 3½ x 3½ |
1/4 |
20 |
77 |
68 |
55 |
42 |
|
|
|
|
|
|
|
|
| 4x4 |
1/4 |
25 |
98 |
89 |
78 |
65 |
51 |
40 |
|
|
|
|
|
|
| 3/8 |
28 |
132 |
119 |
102 |
85 |
64 |
|
|
|
|
|
|
|
| 5x5 |
1/4 |
36 |
137 |
128 |
118 |
107 |
94 |
80 |
64 |
|
|
|
|
|
| 3/8 |
40 |
185 |
172 |
158 |
141 |
124 |
103 |
82 |
|
|
|
|
|
| 1/2 |
44 |
229 |
212 |
194 |
173 |
150 |
124 |
|
|
|
|
|
|
| 6x6 |
1/4 |
49 |
178 |
169 |
160 |
150 |
138 |
125 |
110 |
95 |
79 |
|
|
|
| 3/8 |
55 |
241 |
228 |
215 |
200 |
183 |
165 |
145 |
124 |
101 |
|
|
|
| 1/2 |
60 |
299 |
283 |
267 |
248 |
226 |
204 |
177 |
151 |
|
|
|
|
| 7x7 |
1/4 |
65 |
221 |
213 |
204 |
194 |
183 |
171 |
158 |
143 |
128 |
111 |
94 |
|
| 3/8 |
72 |
297 |
285 |
273 |
259 |
243 |
227 |
208 |
189 |
168 |
146 |
123 |
|
| 1/2 |
78 |
369 |
354 |
337 |
320 |
301 |
279 |
255 |
230 |
204 |
176 |
|
|
| 8x8 |
1/4 |
82 |
266 |
259 |
251 |
240 |
231 |
218 |
206 |
193 |
178 |
163 |
146 |
128 |
| 3/8 |
90 |
357 |
346 |
334 |
321 |
306 |
291 |
272 |
254 |
236 |
215 |
192 |
168 |
| 1/2 |
98 |
440 |
427 |
412 |
395 |
377 |
355 |
334 |
311 |
286 |
259 |
231 |
201 |
| 10x10 |
1/4 |
122 |
364 |
357 |
349 |
340 |
330 |
320 |
308 |
296 |
282 |
267 |
252 |
236 |
| 3/8 |
132 |
482 |
471 |
460 |
448 |
435 |
419 |
404 |
388 |
369 |
350 |
331 |
308 |
| 1/2 |
142 |
592 |
579 |
566 |
550 |
533 |
515 |
495 |
474 |
453 |
428 |
403 |
375 |
* Load
Tables Based on Fy=46ksi
|
|
Dean Lally L.P. -
Fire-Trol Columns
420 Woodruff Road
Joliet, IL 60432
Toll Free: (800) 323-5514
Direct Phone: (815) 726-2007
FAX: (815) 726-2928 |